FXS Blade Operation Alarm
This alarm is applicable only to MP-1288.
acModuleOperationAlarm
Alarm |
acModuleOperationalAlarm |
||
---|---|---|---|
OID |
1.3.6.1.4.1.5003.9.10.1.21.2.0.123 |
||
Description |
The alarm is sent when an operational hardware failure occurs on the FXS ports or on the FXS blades (DSP and CPU). |
||
Alarm Source |
Chassis/Module# (Analog / CPU) |
||
Event Type |
equipmentAlarm |
||
Probable Cause |
equipmentMalfunction |
||
Severity |
Condition |
Text |
Corrective Action |
Major |
Operational hardware failure on more than 33% of FXS ports on the FXS blade. |
"Operational failure was detected on Analog/CPU blade" |
Service the faulty FXS blade. |
Operational DSP/CPU hardware failure on the FXS blade and the problem could not be resolved after successive restart attempts. |
"Blade is out-of-service due to operational failure" |
Cold restart (power off and then on) the device to return the blade to service. |
|
Minor |
Operational hardware failure on up to 33% of FXS ports on the FXS blade. Major to Minor: hardware failure on less than 25% of the FXS ports on the FXS blade. |
"Operational failure was detected on Analog/CPU blade" |
Service the faulty blade. |
Clear |
No hardware failure on any of the FXS ports on the FXS blade. |
|
|