FXS Blade Operation Alarm

This alarm is applicable only to MP-1288.

acModuleOperationAlarm

Alarm

acModuleOperationalAlarm

OID

1.3.6.1.4.1.5003.9.10.1.21.2.0.123

Description

The alarm is sent when an operational hardware failure occurs on the FXS ports or on the FXS blades (DSP and CPU).

Alarm Source

Chassis/Module# (Analog / CPU)

Event Type

equipmentAlarm

Probable Cause

equipmentMalfunction

Severity

Condition

Text

Corrective Action

Major

Operational hardware failure on more than 33% of FXS ports on the FXS blade.

"Operational failure was detected on Analog/CPU blade"

Service the faulty FXS blade.

Operational DSP/CPU hardware failure on the FXS blade and the problem could not be resolved after successive restart attempts.

"Blade is out-of-service due to operational failure"

Cold restart (power off and then on) the device to return the blade to service.

Minor

Operational hardware failure on up to 33% of FXS ports on the FXS blade.

Major to Minor: hardware failure on less than 25% of the FXS ports on the FXS blade.

"Operational failure was detected on Analog/CPU blade"

Service the faulty blade.

Clear

No hardware failure on any of the FXS ports on the FXS blade.